The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surgery.

Roberto PessoaRafael SiqueiraJunying LiIslam SalehPriscila MeneghettiFábio BezerraHom-Lay WangGustavo Mendonca
Published in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2021)
The use of surgical guides with or without fixation pins can provide clinically acceptable outcomes in terms of accuracy in implant position. There was a statistically significant difference in the accuracy of implant position when utilizing fixation pins only for horizontal apical and depth deviation. Additionally, a statistically significant difference between the planned and the 3D printed surgical guide when considering the sleeve position was detected.