A Segmental 2D Readout Board Manufactured in Printed Circuit Board Technology for Gas Electron Multiplier Detectors.
Michał BabijPiotr BielówkaSzymon GburekKarol MalechaPublished in: Sensors (Basel, Switzerland) (2023)
The Gas Electron Multiplier (GEM) was introduced by Fabio Sauli in 1997. This technology is broadly used in current and planned High-Energy Physics (HEP) experiments. One of the key components of these detectors is a readout board, which collects charges amplified by GEM foils and transfers them to readout electronics. The commonly used Cartesian XY readout boards are manufactured from the same type of polyamide film used to produce the GEM foils. The manufacturing process utilizes a deep polyimide etching, similar to the Micro Chemical Vias (MCV) etching process, which is protected by patent. The material prepared in this way is glued onto a rigid substrate and mounted in a detector. The production process was developed at CERN, and the technology has been commercialized to a small extent. Consequently, only a few research centers have the ability to make dedicated readout strips readouts. GEM detectors are characterized by a segmented structure that allows the separation of an electron-multiplying structure from a readout. This feature enables the implementation of a new type of charge reading system without the need to interfere with the GEM foil system. A new approach is proposed to simplify production and reduce the costs of GEM detector readout boards. It is based on the concept of segmental readout structures that are manufactured in standard Printed Circuit Board (PCB) technology. The interconnectors and mountings are located on the back of the bottom, so it is possible to place the readout electronics behind the readout plate. The boards are designed in such a way that they can be panelized into a readout with a more extensive active area. The margin between PCBs is minimalized to approximately 200 µm, which is less than 1% of the 70 × 70 mm 2 board area, so the active area is as big as possible. Therefore, this solution gives us the ability to further increase the size of a readout by adding additional segments, which reduces the cost of scaling up the detector size. A few research groups have suggested similar solutions that utilize PCB technology, but currently, only detectors with 1D zigzag readouts have been validated and used. The measurement results of other 2D (XY) redouts using PCB technology have not been presented. The measurements shown and discussed in this paper validated the proposed technology. X-ray radiographs were obtained, validating the ability to use this technology to manufacture readout boards for GEM detectors. In opposition to state-of-the-art readouts, the proposed solution can be manufactured by any PCB manufacturer without using MCV-patented technology. This gives the users flexibility in designing and ordering low-cost custom readouts.