Vacuum assisted and gravitational venous drainage in aortic valve surgery: A propensity-match study.
Raffaele SilvanoPietro Giorgio MalvindiFrancesca MazzoccaStefania GenovaEmanuele Di CampliFrancesca PaternaJacopo M D'EsteJacopo AlfonsiPaolo BerrettaChristopher MunchMarco Di EusanioPublished in: Perfusion (2024)
The use of VAVD during isolated aortic valve replacement was not associated with increased risks of postoperative complications and in-hospital mortality with results that were at least similar to those registered in a matched cohort of patients operated on with GVD.