Effect of Asymmetric Fins on Thermal Performance of Phase Change Material-Based Thermal Energy Storage Unit.

Muhammad ShabanTalha Irfan KhanMuhammad AnwarMeshal AlzaidRakan Alanazi
Published in: Materials (Basel, Switzerland) (2023)
Phase change material (PCM)-based thermal energy storage units (TESU) have very low thermal conductivity that compromise their charging and discharging rate. The present study focuses on an enhancement in charging rate as well as an increase in the uniformity of the melting rate. A rectangular cavity consisting of two horizontal partial fins is studied. The horizontal partial fins are placed symmetrically in a PCM-based TESU. In the current work, the melting rate of PCM was enhanced using asymmetric arrangement while keeping all other parameters the same, thus showing the positive effect of asymmetric configuration in such storage systems. The position and the pitch of each fin is optimized to improve heat transfer characteristics of the TESU. The numerical investigation of the problem is performed. TESU with asymmetrically placed fins show better performance in terms of higher charging rate as well as uniformity of the charging rate. The asymmetric placement of the fins suggested by present study increased the charging rate by 74.3% on average as compared to the symmetrically placed fins in the storage system. The charging rate uniformity is improved by 43.7%. The asymmetric fin's placement conserved the convection strength for a longer melting duration and so increased the Nusselt number by 80.2% as compared to the symmetrically placed fins. Thus, it can be concluded that the performance of asymmetric fins is better in the charging of PCMs than the symmetrically placed fins in a PCM-based TESU.
Keyphrases
  • high resolution
  • solid state
  • magnetic resonance