Login / Signup

Mortality Following Treatment With and Without Paclitaxel-Coated Devices in Dialysis Patients.

Tanja BöhmeElias NooryUlrich BeschornerBörries JacquesKarlheinz BürgelinVincent HofmannThomas NührenbergFranz-Josef NeumannThomas Zeller
Published in: Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists (2022)
After the publication of Katsanos's metaanalyses, the uncertainty regarding PTX device safety in peripheral interventions in patients mainly without end-stage renal insufficiency was initially considerable. The present study for the first time investigates the potential long-term mortality risk of dialysis patients following PTX device treatment of PAD. In contrast to a recent meta-analysis, this real-world study could show a better survival after PTX treatment in comparison to uncoated devices.