In this retrospective study of 982 matched patients undergoing sleeve gastrectomy, the ECHELON FLEX™ GST system was associated with a lower rate of hemostasis-related complications as compared with the Signia™ Stapling System. Further controlled prospective studies are needed to confirm the validity of this finding.