Appropriate mesh size in the totally extraperitoneal repair of groin hernias based on the intraoperative measurement of the myopectineal orifice.
Masafumi InomataYuji ShigemitsuTsuyoshi EtohYohei KonoKosuke SuzukiKenji ZezeMasafumi InomataPublished in: Surgical endoscopy (2020)
The appropriate mesh size for TEP repair, derived from intraoperative MPO measurements, was estimated as 13.2 × 10.4 cm and 15.6 × 13.0 cm when the hernia orifice was < 3 cm and ≥ 3 cm, respectively. Using appropriate mesh sizes based on MPO measurement may reduce groin hernia recurrence after TEP.
Keyphrases