Login / Signup

Feasibility of diaphragm pacing in patients after bilateral lung transplantation.

Dries TestelmansPhilippe NafteuxSophie Van CromphautBart VrijsenRobin VosPaul De LeynHerbert DecaluwéDirk Van RaemdonckGeert M VerledenBertien Buyse
Published in: Clinical transplantation (2017)
Recent animal studies and intraoperative studies in humans suggested that phrenic nerve stimulation could attenuate ventilator-induced diaphragm dysfunction. The purpose of the present study is to examine the safety and feasibility of diaphragm pacing during the weaning process after bilateral lung transplantation. Four patients, suffering from chronic pulmonary disease, were included, and diaphragm pacing was evaluated after lung transplantation. Implantation of electrodes at the end of the lung transplant procedure was possible in three of the four patients. In all implanted patients, stimulation of the diaphragm could trigger the ventilator. Implanted electrodes were completely removed by percutaneous retraction after up to 7 days of pacing. Adverse events related to pacing included occurrence of pain. Diaphragm pacing with temporary electrodes, inserted during surgery, is feasible and is able to trigger the ventilator in patients after bilateral lung transplantation. The use of intradiaphragmatic electrodes creates the additional opportunity to monitor the evolution of diaphragm electromyography during the postoperative weaning process.
Keyphrases