Novel Criteria for the Observe-Zone of the ESC 0/1h-hs-cTnT Algorithm.

Pedro Lopez-AyalaThomas NestelbergerJasper BoeddinghausLuca KoechlinPaul David RatmannIvo StrebelJuliane GehrkeSeverin MeierJoan WalterMaria Rubini GimenezEugenio MutschlerÒscar MiróBeatriz López-BarbeitoFrancisco Javier Martín-SánchezEsther Rodríguez-AdradaDagmar I KellerL Kristin NewbyRaphael TwerenboldEvangelos GiannitsisBertil LindahlChristian E Muellernull null
Published in: Circulation (2021)
A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.