Anterior cervical discectomy and fusion with a dynamic translational plating versus a rigid carbon fiber reinforced PEEK plating system - a comparison study of radiographic parameters.
Benedikt W BurkhardtMena G KerolusChristopher D WitiwJoachim M OertelRichard G FesslerPublished in: British journal of neurosurgery (2021)
ACDF allows for correction and maintenance of cervical alignment. Rigid rigid plate appears more effective at maintaining segmental lordotic correction. The fusion rate and implant failure was not different for both groups.