Potential for Dose Reduction in CT-Derived Left Ventricular Ejection Fraction: A Simulation Study.
Martin Weber KuskSoren HessOke GerkeShane J FoleyPublished in: Tomography (Ann Arbor, Mich.) (2023)
Provided that measurements are performed with papillary muscles excluded from the LV volume, the dose can be reduced by a factor of 20 without significantly affecting LVEF measurements. This corresponds to an effective dose of 1 mSv. CT can potentially be used for LVEF measurement with minimal excessive radiation.