Login / Signup

Dosimetric impact of deformable image registration using radiophotoluminescent glass dosimeters with a physical geometric phantom.

Siwaporn SakulsingharojNoriyuki KadoyaShohei TanakaKiyokazu SatoMitsuhiro NakamuraKeiichi Jingu
Published in: Journal of applied clinical medical physics (2023)
The dose difference observed in our study was 3% for tumor-proxy and within 5% for rectum-proxy. The custom developed physical phantom with inserts showed potential for accurate evaluation of DIR-based dose accumulation. The prospect of simultaneous evaluation of geometric and dosimetric DIR accuracy in a single phantom may be useful for validation of DIR for clinical use.
Keyphrases
  • monte carlo
  • image quality
  • radiation therapy
  • physical activity
  • mental health
  • dual energy
  • deep learning
  • high resolution
  • computed tomography
  • mass spectrometry