Intramedullary nail versus minimally invasive plate osteosynthesis for displaced extraarticular proximal tibia fractures: a prospective comparative cohort study.
Mehdi TeimouriSeyed Peyman MirghaderiJoshua Alan ParryArmin ZiaeiMaryam SalimiMohammad Ali TahririanPublished in: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (2023)
IMN fixation of extraarticular proximal tibia fractures was associated with a shorter union time and better functional scores compared to MIPO.