Login / Signup

Ridge augmentation-The new field of computerized guided surgery: A technical note for minimal-invasive bone splitting.

Vasilios AlevizakosGergo MitovMarcus SchillerConstantin von See
Published in: Clinical case reports (2021)
Different instrumentation procedures of the alveolar ridge expansion technique (ARST) with or without Guided Bone Regeneration have proven to be effective for successful implant placement in cases of alveolar bone width between 3mm and 6mm. Conventional bone splitting techniques require flap arising. This technical note demonstrates a method for flapless guided bone splitting. For this purpose, a newly developed surgical guide with internal irrigation channels was used. Using CAD-CAM additive technology, a narrow slot along the field of interest and a pin of a cooling pipe was designed and implemented in a surgical guide template. The bone split was performed flapless through the surgical guide while the cooling pipe was connected to it. During surgery, the piezo-driven instrument was moved within that slot, and the irrigation solution was directly rinsing it at point of entry through the irrigation channel. This procedure was performed on a 3.3 mm wide alveolar ridge achieving over 3 mm of bone gain. The described method combines several positive aspects. The micro-invasive flapless surgical procedure might improve postoperative healing. Additionally, sufficient cooling of the bone might lead to less thermal affection of bone cells and less resorption of the cortical bone. However, systematic studies are needed to confirm the observations of the presented case report.