Determining Adsorption Parameters of Potentially Contaminant-Releasing Materials Using Batch Tests with Differing Liquid-Solid Ratios.
Hirofumi SakanakuraKenichi ItoJiajie TangMikako NakagawaHiroyuki IshimoriPublished in: Materials (Basel, Switzerland) (2021)
Adsorption parameters such as the distribution coefficient are required to predict the release behavior of contaminants using advection-dispersion models. However, for potentially contaminant-releasing materials (PCMs) such as dredged sludge and coal ash, these parameters cannot be obtained by conventional adsorption tests. This study developed a method to determine adsorption parameters for PCMs from a set of batch tests conducted in parallel as a function of the liquid-solid ratio (LS-parallel test). This LS-parallel test was performed on sandy soil derived from marine sediment using liquid-solid ratios from 1 to 300 L/kg. The water-contact time was also changed from 10 min to 28 d to elucidate the kinetics or equilibrium of contaminants released from the sample. Adsorption parameters were successfully obtained if the substance was under adsorption control. A column percolation test was performed to confirm the effectiveness of the obtained parameters. Good agreements were observed for SO42- and B, but discrepancies remained for other substances such as F- and As suggesting that improvements are necessary in both the LS-parallel test procedure and the advection-dispersion model.