Login / Signup

Additively manufactured electrodes for plasma and power-flow studies in high-power transmission lines on the 1-MA MAIZE facility.

T J SmithP C CampbellG V DowhanNicholas M JordanM D JohnstonM E CuneoG R LaityR D McBride
Published in: The Review of scientific instruments (2021)
Power-flow studies on the 30-MA, 100-ns Z facility at Sandia National Laboratories have shown that plasmas in the facility's magnetically insulated transmission lines (MITLs) and double post-hole convolute can result in a loss of current delivered to the load. To study power-flow physics on the 1-MA, 100-ns MAIZE facility at the University of Michigan, planar MITL loads and planar post-hole convolute loads have been developed that extend into the lines of sight for various imaging diagnostics on MAIZE. These loads use 3D-printed dielectric support structures lined with thin foils of either aluminum or stainless steel. The metal foils serve as the current-carrying power-flow surfaces, which generate plasma during the current pulse. The foil thickness (50 µm) and widths (11.5-16 mm) are selected to ensure a sufficient linear current density (0.5-0.7 MA/cm) for plasma formation. Laser backlighting (532 nm) and visible-light self-emission imaging capture the overall plasma evolution in the anode-cathode gaps, including the gap closure velocities (1-4 cm/μs).