Login / Signup

Estimation of differential renal function on routine abdominal imaging employing compressed-sensed contrast-enhanced MR: a feasibility study referenced against dynamic renal scintigraphy in patients with deteriorating renal retention parameters.

Victor Schulze-ZachauDavid Jean WinkelFelix KaulTheo DemerathSilke PotthastTobias J HeyeDaniel T Boll
Published in: Abdominal radiology (New York) (2023)
High temporal and spatial resolution GRASP MR imaging allows to identify several degrees of renal function impairment using routine clinical imaging with a high degree of accuracy.
Keyphrases