Login / Signup

Reduction in Olfactory Discomfort in Inhabited Premises from Areas with Mofettas through Cellulosic Derivative-Polypropylene Hollow Fiber Composite Membranes.

Paul Constantin AlbuAndreia PîrțacLudmila MotelicaAurelia Cristina NechiforGeani Teodor ManAlexandra Raluca GrosuSzidonia-Katalin TanczosVlad-Alexandru GrosuGheorghe Nechifor
Published in: Materials (Basel, Switzerland) (2024)
Hydrogen sulfide is present in active or extinct volcanic areas (mofettas). The habitable premises in these areas are affected by the presence of hydrogen sulfide, which, even in low concentrations, gives off a bad to unbearable smell. If the living spaces considered are closed enclosures, then a system can be designed to reduce the concentration of hydrogen sulfide. This paper presents a membrane-based way to reduce the hydrogen sulfide concentration to acceptable limits using a cellulosic derivative-propylene hollow fiber-based composite membrane module. The cellulosic derivatives considered were: carboxymethyl-cellulose (NaCMC), P1; cellulose acetate (CA), P2; methyl 2-hydroxyethyl-cellulose (MHEC), P3; and hydroxyethyl-cellulose (HEC), P4. In the permeation module, hydrogen sulfide is captured with a solution of cadmium that forms cadmium sulfide, usable as a luminescent substance. The composite membranes were characterized by SEM, EDAX, FTIR, FTIR 2D maps, thermal analysis (TG and DSC), and from the perspective of hydrogen sulfide air removal performance. To determine the process performances, the variables were as follows: the nature of the cellulosic derivative-polypropylene hollow fiber composite membrane, the concentration of hydrogen sulfide in the polluted air, the flow rate of polluted air, and the pH of the cadmium nitrate solution. The pertraction efficiency was highest for the sodium carboxymethyl-cellulose (NaCMC)-polypropylene hollow fiber membrane, with a hydrogen sulfide concentration in the polluted air of 20 ppm, a polluted air flow rate (Q H2S ) of 50 L/min, and a pH of 2 and 4. The hydrogen sulfide flux rates, for membrane P1, fall between 0.25 × 10 -7 mol·m 2 ·s -1 for the values of Q H2S = 150 L/min, C H2S = 20 ppm, and pH = 2 and 0.67 × 10 -7 mol·m -2 ·s -1 for the values of Q H2S = 50 L/min, C H2S = 60 ppm, and pH = 2. The paper proposes a simple air purification system containing hydrogen sulfide, using a module with composite cellulosic derivative-polypropylene hollow fiber membranes.
Keyphrases
  • heavy metals
  • ionic liquid
  • metal organic framework
  • molecularly imprinted
  • silver nanoparticles
  • nitric oxide
  • aqueous solution
  • water soluble
  • high resolution
  • mass spectrometry
  • protein kinase