Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture.

Ayush SrivastavPrateek BeheraRavi Kumar DwivediJohn Ashutosh Santoshi
Published in: Indian journal of orthopaedics (2024)
When fixing a transverse scaphoid waist fracture with a single screw, the screw directed posteriorly from either the centre or anterior aspect of the distal pole has the best stability, a parallel configuration has the best stability when fixing it using a screw and a K-wire, and divergent configuration has the best stability when fixing it with two K-wires only.