Cluster behavior in dental implant failure - A scoping review.
Avinash S BidraLuiz Carlos VolpMarissa IversonPublished in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2024)
Cluster behavior occurs in 25% of modern roughened surface implant failures which is significantly less than machined surface cluster implant failures. Nevertheless, the overall prevalence of cluster pattern of implant failure of modern roughened surface implants is reasonably low at 2%.