Evaluation of neuroretinal integrity in optical coherence tomography-graded eyes with partial-thickness macular holes.
Heiko StinoLorenz WassermannRobin RistlClaudette Abela-FormanekMichael GeorgopoulosStefan SacuUrsula Margarethe Schmidt-ErfurthAndreas PollreiszPublished in: Acta ophthalmologica (2022)
In our study cohort, EP are associated with worse VA and advanced neuroretinal tissue loss presenting with wider foveal cavities and thinner foveal floors. During the follow-up period, VA remained stable in all entities of partial-thickness macular holes.