The effect of lens and fitting characteristics upon scleral lens centration.
Damien FisherMichael J CollinsStephen James VincentPublished in: Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) (2024)
Scleral lens decentration remained relatively stable over 90 min of lens wear. A greater initial central fluid reservoir depth resulted in significantly more lens decentration, particularly inferiorly. Large variations in lens thickness, mass or the addition of a single peripheral fenestration did not substantially affect lens centration.