Evaluation of SAMe-TT2R2 Score on Predicting Success With Extended-Interval Warfarin Monitoring.

Andrew Y HwangNicholas W CarrisEric A DietrichJohn G GumsSteven M Smith
Published in: The Annals of pharmacotherapy (2018)
A total of 47 patients receiving chronic anticoagulation completed a median of 36 weeks of extended-interval follow-up. The median baseline SAMe-TT2R2 score was 1 (range 0-5). Lower SAMe-TT2R2 scores appeared to be associated with greater duration of extended-interval follow-up achieved, though the differences between scores were not statistically significant. No individual variable of the SAMe-TT2R2 score was associated with achieved weeks of extended-interval follow-up. Analysis of additional patient factors found that longer duration (≥24 weeks) of prior stable treatment was significantly associated with greater weeks of extended-interval follow-up completed ( P = 0.04). Conclusion and Relevance: This pilot study provides limited evidence that the SAMe-TT2R2 score predicts success with extended-interval warfarin follow-up but requires confirmation in a larger study. Further research is also necessary to establish additional predictors of successful extended-interval warfarin follow-up.
Keyphrases
  • atrial fibrillation
  • venous thromboembolism
  • case report