Login / Signup

Hybrid III Manikin Lumbar Spine Loading Under Vertical Impact.

Narayan YoganandanJason MooreTim A WesterhofNico A Flierman
Published in: Military medicine (2024)
The Hybrid III lumbar spine when subjected to vertical impact simulating underbody blast levels showed that the impact is transmitted via the axial loading mechanism. This finding paralleled the results of axial force predominance over shear forces and axial loading injuries to human spines. Axial forces increased with increasing velocity suggesting the possibility of developing injury assessment risk curves, i.e., the manikin spine does not saturate, and its response is not a step function. It is possible to associate probability values for different force magnitudes. A similar conclusion was found to be true for both magnitudes of added effective torso mass at the superior end of the manikin spinal column. Additional matched-pair tests are needed to develop injury criteria for the Hybrid III male and female lumbar spines.