Login / Signup

Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.

Jaehyun KimSeongyun ParkJi Hyun Ahn
Published in: Archives of orthopaedic and trauma surgery (2021)
In the narrow-version femoral implant group, the ML dimension and the mean modified aspect percentage ratio were smaller than in the standard-version femoral implant group. A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. It was suggested that the cut-off point could be suggested as 135.4% for Anthem TKA design and 133.3% for Persona TKA design. These radiographic parameters are cost-effective and easily applicable for planning a TKA.A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. The cut-off point was 135.4% for Anthem TKA design and 133.3% for Persona TKA design.
Keyphrases
  • total knee arthroplasty
  • total hip
  • psychometric properties
  • soft tissue
  • patients undergoing
  • bone mineral density