Login / Signup

Controlling fluid-induced seismicity during a 6.1-km-deep geothermal stimulation in Finland.

Grzegorz KwiatekTero SaarnoThomas AderFelix BluemleMarco BohnhoffMichael ChendorainGeorg DresenPekka HeikkinenIlmo KukkonenPeter LearyMaria LeonhardtPeter MalinPatricia Martínez-GarzónKevin PassmorePaul PassmoreSergio ValenzuelaChristopher Wollin
Published in: Science advances (2019)
We show that near-real-time seismic monitoring of fluid injection allowed control of induced earthquakes during the stimulation of a 6.1-km-deep geothermal well near Helsinki, Finland. A total of 18,160 m3 of fresh water was pumped into crystalline rocks over 49 days in June to July 2018. Seismic monitoring was performed with a 24-station borehole seismometer network. Using near-real-time information on induced-earthquake rates, locations, magnitudes, and evolution of seismic and hydraulic energy, pumping was either stopped or varied-in the latter case, between well-head pressures of 60 and 90 MPa and flow rates of 400 and 800 liters/min. This procedure avoided the nucleation of a project-stopping magnitude M W 2.0 induced earthquake, a limit set by local authorities. Our results suggest a possible physics-based approach to controlling stimulation-induced seismicity in geothermal projects.
Keyphrases
  • high glucose
  • diabetic rats
  • healthcare
  • oxidative stress
  • quality improvement
  • endothelial cells
  • stress induced