Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.
Aleksa MarkovićZoran LazićTijana MišićMiodrag ŠćepanovićAleksandar TodorovićKaustubh ThakareBojan JanjićZoran VlahovićMirko GlišićPublished in: Vojnosanitetski pregled (2018)
Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.