Comparison of Preoperative Computed Tomography and Intraoperative Estimation in Predicting the Version of a Single-Wedge Femoral Stem.

Jingyang SunYanchao ZhangJunmin ShenQingyuan ZhengTiejian LiBohan ZhangYong-Gang ZhouGuo-Qiang Zhang
Published in: Orthopaedic surgery (2022)
The middle level of femoral neck on CT scan and T line on cutting surface are better references to measure femoral version for predicting postoperative stem version. However, the relationship between stem version and predictive value was flexible. Therefore, further three-dimensional studies of postoperative CT are needed to validate the press-fit fixation and rotational freedom of the single-wedge stem.