Validation of Numerical Simulations of Thoracic Aorta Hemodynamics: Comparison with In Vivo Measurements and Stochastic Sensitivity Analysis.
Alessandro BoccadifuocoAlessandro MariottiKatia CapelliniSimona CeliMaria Vittoria SalvettiPublished in: Cardiovascular engineering and technology (2018)
In summary, a successful integration of hemodynamic simulations and of MRI data for a patient-specific simulation has been shown. The wall compliance seems to have a significant impact on the numerical predictions; a larger wall elasticity generally improves the agreement with experimental data.