Login / Signup

Forensic age estimation based on fast spin-echo proton density (FSE PD)-weighted MRI of the distal radial epiphysis.

Oguzhan EkizogluAli ErMustafa BozdagNegahnaz MoghaddamSilke Grabherr
Published in: International journal of legal medicine (2021)
Radiation exposure is a crucial factor to consider in forensic age estimation. The various magnetic resonance imaging (MRI) modalities used in forensic age estimation avoid radiation exposure. This study examined the reliability of distal radius ossification using fast spin-echo proton density (FSE PD)-weighted MRI to estimate age. Left wrist MRI findings of 532 patients aged 10-29 years were evaluated retrospectively using the five-stage system of Dedouit et al. The intra- and interobserver reliability values were κ = 0.906 and 0.869, respectively. Based on the results, the respective minimum ages estimated for stages 4 and 5 were 13.4 and 16.1 years for females, and 15.1 and 17.3 years for males; the method could not estimate an age of 18 years in any case. FSE PD MRI analysis of the distal radius epiphysis provides supportive data and can be used when evaluating the distal radius for forensic age estimation.