Login / Signup

Utility of serial troponin testing for emergency department patients with syncope.

Cameron W LeafloorAndrew D McRaeEric MercierJustin W YanPaul HuangMuhammad MukarramBrian H RoweAline C IshimweMona HegdekarMarco L A SivilottiMonica TaljaardMarie-Joe NemnomVenkatesh Thiruganasambandamoorthy
Published in: CJEM (2024)
The initial troponin measurement was sufficient for serious adverse event detection and in-ED risk stratification. Serial troponin testing does not improve the diagnostic yield or prognostication and should be reserved for patients with ongoing symptoms or electrocardiogram findings suggestive of cardiac ischemia.
Keyphrases
  • emergency department
  • pulmonary embolism
  • left ventricular
  • heart failure
  • real time pcr
  • depressive symptoms
  • drug induced