Autotransfusion of vaginally shed blood as a novel therapy in obstetric hemorrhage: A case series.
Jaclyn M PhillipsTakahiro TamuraJonathan H WatersJacob LarkinSara SakamotoPublished in: Transfusion (2022)
In 64 cases where autotransfusion of vaginally shed blood occurred, autotransfusion was well tolerated. Heterogeneity in autologous blood volume collection likely represents the lack of standardized protocols for blood collection in the delivery room. Autotransfusion of vaginally shed blood is a feasible and reasonable technique to employ during severe obstetric hemorrhage.