Login / Signup

Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow.

Helen NgoJohannes SpaethStefan Schumann
Published in: PloS one (2024)
Wearing facepieces is discussed in the context of increasing the volume of rebreathed air. We hypothesized that rebreathed air volume increases with increasing filtering facepiece (FFP) class and that persons breathing via facepieces compensate for the additional dead-space. We have determined the effective amount of rebreathed air for a surgical masks and FFP2 and FFP3 respirators in a physical model and determined tidal volumes, breathing frequency, blood oxygen saturation, and transcutaneously measured blood carbon dioxide partial pressure (PCO2) in lung-healthy subjects breathing without and with facepieces at rest and during exercising on a recumbent ergometer. Rebreathed air volume increased with the facepieces' protection class and with increasing inspiration volume by 45 ± 2 ml to 247 ± 1 ml. Ambient airflow reduced rebreathed air volume by 17% up to 100% (all p < 0.001). When wearing facepieces, subjects increased tidal volume (p < 0.001) but not breathing frequency. Oxygen saturation was not influenced by facepieces. With FFP3 respirators PCO2 increased by up to 3.2 mmHg (p < 0.001) at rest but only up to 1.4 mmHg (p < 0.001) when exercising. Discomfort of breathing increased with increasing protection class of the facepiece but was consistently perceived as tolerable. We conclude that the amount of rebreathed air increases with increasing protection class of facepieces. Healthy adults were capable to compensate the facepieces' dead-space by adapting tidal volume at rest and during physical activity; thereby they tolerated moderate increases in PCO2. Ambient airflow may considerably reduce the amount of facepiece related rebreathed air.
Keyphrases
  • carbon dioxide
  • physical activity
  • air pollution
  • particulate matter
  • mental health
  • high intensity