Does concomitant prolactin measurement ıncrease the accuracy of ınferior petrosal sinus sampling?

Tugce ApaydınMehmet YasarFeyyaz BaltaciogluGoncagül HaklarDilek Gogas Yavuz
Published in: Neuroradiology (2022)
Although PRL-adjusted ACTH IPS/P ratios can be helpful to improve the accuracy of results during IPSS procedures, a prolactin intersinus gradient towards the ACTH-dominant side in patients with CD may invalidate PRL as an indicator of pituitary venous outflow.
Keyphrases
  • growth hormone
  • nk cells