Login / Signup

Evaluation of Analytical Performance of Seven Rapid Antigen Detection Kits for Detection of SARS-CoV-2 Virus.

Nahal EshghifarAli BusheriRojeet ShresthaSafedin Beqaj
Published in: International journal of general medicine (2021)
This comparison study shows that rapid antigen tests are less sensitive than RT-PCR tests and are not reliable tests for testing asymptomatic patients, who often carry low viral load. Analytical performance of rapid antigen tests should be thoroughly evaluated before implementing it at clinical decision level.
Keyphrases
  • loop mediated isothermal amplification
  • sars cov
  • sensitive detection
  • real time pcr
  • label free
  • quality improvement