Linear and planar reflection artifacts on swept-source and spectral-domain optical coherence tomography due to hyperreflective crystalline deposits.

Serena FragiottaPedro Fernández-AvellanedaMark Philip BreazzanoLawrence A YannuzziChristine A CurcioK Bailey Freund
Published in: Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie (2019)
To the authors' knowledge, this is the first description of SD- and SS-OCT/OCTA artifacts corresponding to both HCD and the "onion sign." These artifacts are likely due to highly reflective CC previously shown on histology to correspond to both of these OCT signatures.