Plasmonic Approach to Fluorescence Enhancement of Mesoporous Silica-Coated Gold Nanorods for Highly Sensitive Influenza A Virus Detection Using Lateral Flow Immunosensor.
Donggu HongEun-Jung JoDoyeon BangChaewon JungYoung Eun LeeYu-Seon NohMyung Geun ShinMin-Gon KimPublished in: ACS nano (2023)
Rapid diagnostic tests based on the lateral flow immunoassay (LFI) enable early identification of viral infection, owing to simple interpretation, short turnaround time, and timely isolation of patients to minimize viral transmission among communities. However, the LFI system requires improvement in the detection sensitivity to match the accuracy of nucleic acid amplification tests. Fluorescence-based LFIs are more sensitive and specific than absorption-based LFIs, but their performance is significantly affected by fundamental issues related to the quantum yield and photobleaching of fluorophores. Metal-enhanced fluorescence (MEF), which is a plasmonic effect in the vicinity of metallic nanoparticles, can be an effective strategy to improve the detection sensitivity of fluorescence-based LFIs. The key factors for obtaining a strong plasmonic effect include the distance and spectral overlap of the metal and fluorophore in the MEF system. In this study, MEF probes were designed based on core-shell nanostructures employing a gold nanorod core, mesoporous silica shell, and cyanine 5 fluorophore. To optimize the efficiency of MEF probes incorporated on the LFI platform (MEF-LFI), we experimentally and theoretically investigated the distance dependence of plasmonic coupling between cyanine 5 and gold nanorods by adjusting the shell thickness, resulting in significant fluorescence enhancement. The proposed MEF-LFI enabled highly sensitive detection of influenza A virus (IAV) nucleocapsid protein with a detection limit of 0.52 pg mL -1 within 20 min and showed high specificity and accuracy for determining IAV clinical samples. Overall, our findings demonstrate the potential of this method as an effective tool for molecular diagnosis under emergency conditions.
Keyphrases
- single molecule
- label free
- loop mediated isothermal amplification
- sensitive detection
- energy transfer
- nucleic acid
- quantum dots
- atomic force microscopy
- living cells
- small molecule
- real time pcr
- end stage renal disease
- healthcare
- public health
- fluorescent probe
- ejection fraction
- sars cov
- prognostic factors
- emergency department
- computed tomography
- chronic kidney disease
- magnetic resonance imaging
- newly diagnosed
- molecular dynamics
- high throughput
- magnetic resonance
- fluorescence imaging
- photodynamic therapy
- molecularly imprinted
- patient reported
- binding protein
- protein protein
- high speed
- patient reported outcomes
- solid phase extraction