Elemental Fluorine Detection by Dielectric Barrier Discharge Coupled to Nanoelectrospray Ionization Mass Spectrometry for Nontargeted Analysis of Fluorinated Compounds.
Kunyu ZhengJoseph E LesniewskiMichael J DolanWanqing LiTyler T MetalloKaveh JorabchiPublished in: Analytical chemistry (2020)
The growing use of fluorochemicals has elevated the need for nontargeted detection of unknown fluorinated compounds and transformation products. Elemental mass spectrometry (MS) coupled to chromatography offers a facile approach for such analyses by using fluorine as an elemental tag. However, efficient ionization of fluorine has been an ongoing challenge. Here, we demonstrate a novel atmospheric-pressure elemental ionization method where fluorinated compounds separated by gas chromatography (GC) are converted to Na2F+ for nontargeted detection. The compounds are first introduced into a helium dielectric barrier discharge (DBD) for breakdown. The plasma products are subsequently ionized by interaction with a nanoelectrospray ionization (nano-ESI) plume of sodium-containing aqueous electrolytes. Our studies point to HF as the main plasma product contributing to Na2F+ formation. Moreover, the results reveal that Na2F+ is largely formed by the ion-neutral reaction between HF and Na2A(NaA)n+, gas-phase reagent ions produced by nano-ESI where A represents the anion of the electrolyte. Near-uniform fluorine response factors are obtained for a wide range of compounds, highlighting good efficiency of HF formation by DBD regardless of the chemical structure of the compounds. Detection limits of 3.5-19.4 pg of fluorine on-column are obtained using the reported GC-DBD-nano-ESI-MS. As an example of nontargeted screening, extractions from oil-and-water-repellent fabrics are analyzed via monitoring Na2F+, resulting in detection of a fluorinated compound on a clothing item. Notably, facile switching of the ion source to atmospheric-pressure chemical ionization with the exact same chromatographic method allows identification of the detected compound at the flagged retention time.
Keyphrases
- gas chromatography
- mass spectrometry
- high resolution mass spectrometry
- liquid chromatography
- tandem mass spectrometry
- ms ms
- gas chromatography mass spectrometry
- high performance liquid chromatography
- loop mediated isothermal amplification
- positron emission tomography
- capillary electrophoresis
- high resolution
- real time pcr
- simultaneous determination
- solid phase extraction
- ionic liquid
- pet imaging
- computed tomography
- particulate matter
- genome wide
- single cell
- gene expression
- molecular dynamics
- ion batteries
- sensitive detection