Login / Signup

Co-registration of cone beam CT and preoperative MRI for improved accuracy of electrode localization following cochlear implantation.

A S DragovicA K StringerL CampbellC ShaulStephen J O'LearyR J Briggs
Published in: Cochlear implants international (2018)
CBCT should be performed following adult cochlear implantation for audit and quality control of surgical technique. If SV insertion or translocation is suspected, co-registration with preoperative MRI should be performed to enable easier analysis. There will be a learning curve for this process in terms of both the co-registration and the interpretation of images by clinicians.