Multicentre randomised controlled trial comparing standard and high resolution optical technologies in colorectal cancer screening.
Simona Di CaroLucia FiniRoser VegaKonstantinos C FragkosSunil DolwaniJohn GreenLesley-Ann SmithConrad BeckettEwen CameronMatthew BanksPublished in: Frontline gastroenterology (2019)
PDR and ADR were not significantly different between devices. The high-resolution colonoscopy system HD-PHL may improve polyp detection as compared with standard resolution technology in detecting flat adenomas. This advantage may have clinically significant implications for missed lesion rates and post-colonoscopy interval colorectal cancer rates.