5-Year outcomes after transcatheter aortic valve implantation: Focus on paravalvular leakage assessed by echocardiography and hemodynamic parameters.

Simon SchoechlinManuel HeinTim BrennemannMartin EichenlaubUndine SchulzNikolaus JanderFranz-Josef Neumann
Published in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2022)
Even mild PVL assessed by echocardiography was an independent predictor for 5-year survival, whereas hemodynamic measurements did not help to identify PVLs that are relevant to 5-year survival.