A Novel Dielectric Modulated Gate-Stack Double-Gate Metal-Oxide-Semiconductor Field-Effect Transistor-Based Sensor for Detecting Biomolecules.

Dibyendu ChowdhuryBishnu Prasad DeBhargav AppasaniNavaneet Kumar SinghRajib KarDurbadal MandalNicu BizonPhatiphat Thounthong
Published in: Sensors (Basel, Switzerland) (2023)
In this article, the performance of n-type junctionless (JL) double-gate (DG) MOSFET-based biosensors with and without gate stack (GS) has been studied. Here, the dielectric modulation (DM) method is applied to detect biomolecules in the cavity. The sensitivity of n-type JL-DM-DG-MOSFET and n-type JL-DM-GSDG-MOSFET-based biosensors have also been evaluated. The sensitivity (ΔV th ) improved in JL-DM-GSDG MOSFET/JL-DM-DG-MOSFET-based biosensors for neutral/charged biomolecules is 116.66%/66.66% and 1165.78%/978.94%, respectively, compared with the previously reported results. The electrical detection of biomolecules is validated using the ATLAS device simulator. The noise and analog/RF parameters are compared between both biosensors. A lower threshold voltage is observed in the GSDG-MOSFET-based biosensor. The I on /I off ratio is higher for DG-MOSFET-based biosensors. The proposed GSDG-MOSFET-based biosensor demonstrates higher sensitivity than the DG-MOSFET-based biosensor. The GSDG-MOSFET-based biosensor is suitable for low-power, high-speed, and high sensitivity applications.
Keyphrases
  • label free
  • high speed
  • gold nanoparticles
  • quantum dots
  • glycemic control
  • metabolic syndrome
  • air pollution
  • single cell
  • insulin resistance
  • high resolution
  • ionic liquid
  • weight loss
  • real time pcr