Accuracy of predictive equations in guiding tracheal intubation depth in children: A prospective study.

Puneet KhannaHeena GargBikash Ranjan RayAjay SinghRiddhi KunduRenu Sinha
Published in: Paediatric anaesthesia (2021)
Formulas based on the demographic variables and middle finger length showed good correlation with the actual ETT depth in children aged 1-4 years. The percentage of accurate ETT depth placements was higher with middle finger length and age-based formulae.
Keyphrases
  • optical coherence tomography
  • young adults
  • cardiac arrest