Left bundle branch area pacing is superior to right ventricular septum pacing concerning depolarization-repolarization reserve.
Jingfeng WangYixiu LiangWei WangXueying ChenJin BaiHaiyan ChenYangang SuRuizhen ChenJunbo GePublished in: Journal of cardiovascular electrophysiology (2019)
LBBAP proves to be a feasible and safe pacing procedure with better depolarization-repolarization reserve, which may predict lower risk of ventricular arrhythmia and sudden cardiac death.