Pipeline steel has considerable risk of corrosion in the high voltage direct current interference cases. Thus, under high potential/current density conditions, the anodic polarization behaviour of X80 steel in Na 2 SO 4 solution and the influence of Cl - ions were investigated using reversed potentiodynamic polarization, the current interrupt method, galvanostatic polarization, scanning electron microscopy, and X-ray photoelectron spectroscopy. In the Na 2 SO 4 solution free of Cl - ions, steel was passivated above 0.120 A cm -2 and the potential increased from -0.32 V to 1.43 V. The passive film was composed of Fe 3 O 4 , γ-Fe 2 O 3 , and FeOOH. The addition of Cl - ions observably influenced the passivation by attacking the passivate film. Low concentration of Cl - ions (<5 mg L -1 NaCl) could set higher demands of current density to achieve passivation and increase the requirement of potential to maintain passivation. A high concentration of Cl - ions (>5 mg L -1 NaCl) completely prevented passivation, showing strong corrosiveness. Thus, the X80 steel was corroded even under high-current-density conditions. The corrosion products were mainly composed of Fe 3 O 4 , α-Fe 2 O 3 , and FeOOH.