A compact and high-performance setup of capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C 4 D).
Lin LiYun-Peng SongDou-Dou RenTang-Xiu LiMing-Hui GaoLei ZhouZhi-Cong ZengQi-Aosheng PuPublished in: The Analyst (2024)
Capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C 4 D) has the advantages of high throughput (simultaneous detection of multiple ions), high separation efficiency (higher than 10 5 theoretical plates) and rapid analysis capability (less than 5 min for common inorganic ions). A compact CE-C 4 D system is ideal for water quality control and on-site analysis. It is suitable not only for common cations ( e.g. Na + , K + , Li + , NH 4 + , Ca 2+ , etc .) and anions ( e.g. Cl - , SO 4 2- , BrO 3 - , etc .) but also for some ions ( e.g. lanthanide ions, Pb 2+ , Cd 2+ , etc .) that require complex derivatization procedures to be detected by ion chromatography (IC). However, an obvious limitation of the CE-C 4 D method is that its sensitivity ( e.g. 0.3-1 μM for common inorganic ions) is often insufficient for trace analysis ( e.g. 1 ppb or 20 nM level for common inorganic ions) without preconcentration. For this technology to become a powerful and routine analytical technique, the system should be made compact while maintaining trace analysis sensitivity. In this study, we developed an all-in-one version of the CE-C 4 D instrument with custom-made modular components to make it a convenient, compact and high-performance system. The system was designed using direct digital synthesis (DDS) technology to generate programmable sinusoidal waveforms with any frequency for excitation, a kilovolt high-voltage power supply for capillary electrophoresis separation, and an "effective" differential C 4 D cell with a low-noise circuitry for high-sensitivity detection. We characterized the system with different concentrations of Cs + , and even a low concentration of 20 nM was detectable without preconcentration. Moreover, the optimized CE-C 4 D setup was applied to analyse mixed ions at a trace concentration of 200 nM with excellent signal-to-noise ratios. In typical applications, the limits of detection based on the 3 σ criterion (without baseline filtering) were 9, 10, 24, 5, and 12 nM for K + , Cs + , Li + , Ca 2+ , and Mg 2+ , respectively, and about 7, 6, 6 and 6 nM for Br - , ClO 4 - , BrO 3 - and SO 4 2- , respectively. Finally, the setup was also applied for the analysis of all 14 lanthanide ions and rare-earth minerals, and it showed an improvement in sensitivity by more than 25 times.
Keyphrases
- capillary electrophoresis
- mass spectrometry
- quantum dots
- loop mediated isothermal amplification
- liquid chromatography
- aqueous solution
- energy transfer
- water soluble
- high throughput
- photodynamic therapy
- label free
- ionic liquid
- single cell
- quality control
- ms ms
- stem cells
- high performance liquid chromatography
- single molecule
- mesenchymal stem cells
- risk assessment
- room temperature
- simultaneous determination