Speed and accuracy of saccades in patients with glaucoma evaluated using an eye tracking perimeter.

Andrew J TathamIan C MurrayAlice D McTrustyLorraine A CameronAntonios PerperidisHarry M BrashBrian W FleckRobert A Minns
Published in: BMC ophthalmology (2020)
Patients with glaucoma had significant differences in eye movements compared to healthy subjects, with a relationship between slower and less accurate eye movements and worse glaucoma severity. However, in a multivariable model, eye movement parameters were not of additional benefit in differentiating eyes with glaucoma from healthy controls.