Compartment Syndrome Secondary to Intraosseous Access Abutting Tibial Stem Cement Mantle of a Total Knee Arthroplasty: A Case Report.
Morad ChughtaiAaron PangTaiba KhanWilliam A CantrellNathan W MeskoTarun K JellaPublished in: JBJS case connector (2022)
Healthcare providers should be cognizant of potential orthopaedic hardware that can impede proper introduction of IO access.