Login / Signup

Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping.

Surya Pratap SinghPriya JagiaVineeta OjhaTulika SethNitish NaikKartik P GangaSanjeev Kumar
Published in: The Indian journal of radiology & imaging (2023)
Purpose  T2* is the gold standard for iron quantification in liver as well as myocardium. In this study, we evaluated the diagnostic accuracy of myocardial T1 mapping for the assessment of myocardial iron overload (MIO) as compared to the T2* mapping in patients with thalassemia major (TM). Methods  Consecutive TM patients attending the thalassemia clinic were prospectively enrolled. Magnetic resonance imaging was performed on a 1.5 T scanner (Siemens Healthineers, Germany) using a gradient echo T2* as well as a T1 mapping (MOLLI) sequence done at a mid-ventricular short-axis single 8 mm slice of the left ventricle. Values were analyzed by manually drawing a region of interest in the mid-septum. T2*less than 20ms was used as the cutoff for significant MIO. Results  One-hundred three patients (58 males, mean age: 17 ± 7.8 years, mean ferritin: 2009.5 µg/L) underwent cardiovascular magnetic resonance. Median T2* of myocardium was 33.45ms. Nineteen patients (18.4%) had T2*less than 20ms. T1 value was low (<850ms) in all the patients with T2* less than 20 ms. Receiver operating characteristic curve analysis revealed the best cutoff of native T1 mapping value as 850 ms which had high specificity (95.2%), sensitivity (94.2%) and negative predictive value (98.8%) for T2* less than 20ms. There was excellent agreement between T1 and T2* for diagnosis of MIO (Kappa-0.848, p <0.001). We did not find any patient who had normal T1 mapping values but had MIO on T2*. Conclusion  T1 and T2* correlate well and normal T1 values may rule out presence of MIO. T1 mapping can act as additional imaging marker for MIO and may be helpful in centers with nonavailability or limited experience of T2*.
Keyphrases