Login / Signup

Validation of the estimation of the macrovascular contribution in multi-timepoint arterial spin labeling MRI using a 2-component kinetic model.

Merlijn C E van der PlasMartin CraigSophie SchmidMichael A ChappellMatthias J P van Osch
Published in: Magnetic resonance in medicine (2021)
Inclusion of a gamma dispersion kernel resulted in better fitting of the model to the data. The separation of the macrovascular and tissue component is affected by the inclusion of a gamma dispersion kernel and the temporal resolution of the ASL dataset.
Keyphrases
  • magnetic resonance imaging
  • single molecule
  • contrast enhanced
  • computed tomography
  • magnetic resonance
  • liquid chromatography
  • diffusion weighted imaging